| Electrical - Rough In |
Failed |
Disapproved |
|
May 10, 2023 12:00 AM |
Brian Dillard |
|
1-add outlet on wall greater than 2" in kitchen at powder room
2-multi gang switch box in top front bath needs to calk unused entries that were opened up |
|
| Electrical - Final |
Failed |
Disapproved |
|
November 2, 2023 12:00 AM |
Brian Dillard |
|
1-closet light clearance at master closet (closet closest to bedroom entry door)
2-need fire rings at switches on kitchen counter
3-cannot have class 1 and class 2 conductors in same box without separation at door bell transformer
4-outlet box not secured left of powder room at kitchen |
|
| Electrical - Spot Check |
Available |
|
|
|
|
|
|
|
| Electrical - Service Pole |
Available |
|
|
|
|
|
|
|
| Electrical - Temporary Service |
Available |
|
|
|
|
|
|
|
| Electrical - Above Ceiling |
Available |
|
|
|
|
|
|
|
| Electrical - Stocking |
Available |
|
|
|
|
|
|
|
| Electrical - Underground |
Available |
|
|
|
|
|
|
|
| Electrical - Panels/Service |
Available |
|
|
|
|
|
|
|
| Electrical - Roof Top |
Available |
|
|
|
|
|
|
|
| Electrical - Floor Heat |
Available |
|
|
|
|
|
|
|
| Electrical - Rough In |
Passed |
Approved |
|
May 11, 2023 12:00 AM |
Brian Dillard |
|
|
|
| Electrical - Final |
Passed |
Approved for Occupancy |
|
November 9, 2023 3:52 PM |
Preston Byrd |
|
|
|