| BUILDING - Footing |
Available |
|
|
|
|
|
|
|
| BUILDING - Foundation |
Available |
|
|
|
|
|
|
|
| BUILDING - Slab |
Passed |
Not Applicable |
|
May 22, 2023 12:00 AM |
Peter Gervais |
|
Per design professional form online |
|
| BUILDING - Framing |
Failed |
Disapproved |
|
May 22, 2023 12:00 AM |
Peter Gervais |
|
1) Seal 10 ft horizontal draft stopping and holes at studs throughout 2) Install shims at jack studs throughout 3) Seal fire blocking and knee wall stairs 4) Complete installation of front porch per S3 and SD2.1 not framed 5) Seal holes in bottom plate at at knee wall kitchen 6) Seal top of chase front of stair landing 2nd floor 7) Complete blocking at roof truss per S0.0 all exterior wall note and detail on SD2 blocking for roof trusses 8) Missing uplift on roof truss see details sheets 9) Missing roof truss braces see detail sheets - Notes: hole in slab at tub, over notched gable floor truss back wall 2nd fl at lineset, dormer not visible per RS |
|
| BUILDING - Insulation |
Passed |
Approved |
|
June 6, 2023 12:00 AM |
Peter Gervais |
|
Batts in concealed attic space |
|
| BUILDING - Final |
Failed |
Disapproved |
|
November 15, 2023 7:32 AM |
Steve Crist |
|
Unit locked, no superintendent on site, no contact information provided. |
|
| BUILDING - Spot Check |
Available |
|
|
|
|
|
|
|
| BUILDING - Other |
Available |
|
|
|
|
|
|
|
| BUILDING - Angle |
Available |
|
|
|
|
|
|
|
| BUILDING - Final/Multi-Family |
Available |
|
|
|
|
|
|
|
| BUILDING - Above Ceiling |
Available |
|
|
|
|
|
|
|
| BUILDING - Stocking |
Available |
|
|
|
|
|
|
|
| BUILDING - Framing |
Failed |
Disapproved |
|
June 1, 2023 12:00 AM |
Peter Gervais |
|
Insulating building without approval. No plans in the box. No inspection done. No phone number provided. Drove around site don't observed GC, no GC onsite. - pictures in workforce - carry over - 1) Seal 10 ft horizontal draft stopping and holes at studs throughout 2) Install shims at jack studs throughout 3) Seal fire blocking and knee wall stairs 4) Complete installation of front porch per S3 and SD2.1 not framed 5) Seal holes in bottom plate at at knee wall kitchen 6) Seal top of chase front of stair landing 2nd floor 7) Complete blocking at roof truss per S0.0 all exterior wall note and detail on SD2 blocking for roof trusses 8) Missing uplift on roof truss see details sheets 9) Missing roof truss braces see detail sheets |
|
| BUILDING - Framing |
Failed |
Disapproved |
|
June 2, 2023 12:00 AM |
Peter Gervais |
|
8) Missing uplift on roof truss see details sheets 9) Missing roof truss braces see detail sheets - Note: no depth indicators in attic space |
|
| BUILDING - Framing |
Passed |
Approved |
|
June 6, 2023 12:00 AM |
Peter Gervais |
|
Previous items completed |
|
| BUILDING - Insulation |
Passed |
Approved |
|
July 10, 2023 12:00 AM |
Peter Gervais |
|
Door installed at garage and sealed
|
|
| BUILDING - Final |
Failed |
Disapproved |
|
November 16, 2023 12:46 PM |
Steve Crist |
|
1) Provide concrete tickets and termite report 2) post EEC under kitchen sink 3) Insulation disturbed behind furnace and across from pulldown 4) Screw garage sheetrock edge 16 in. OC |
|
| BUILDING - Final |
Failed |
Disapproved |
|
November 20, 2023 12:50 PM |
Steve Crist |
|
Disturbed insulation in attic. |
|
| BUILDING - Final |
Passed |
Approved for Occupancy |
|
November 21, 2023 12:24 PM |
Steve Crist |
|
engineering, county utilities signoffs required |
|