Type | Status | Outcome | Cost | Date | Inspector | Checklist | Inspector Notes | General Notes |
---|---|---|---|---|---|---|---|---|
Electrical - Rough In | Failed | Disapproved | 100 | March 6, 2023 4:00 PM | Preston Byrd | 1. Need nail plates where drilled holes are less than 1 1/4" to inside or outside of framing throughout home. 2. Strap NM cable within 12" of outside panel. 3. Need framing for light bracket in ceiling to left of kitchen sink. 4. Need minimum of 3" of wire at each outlet throughout home before any splices are made. 5. Fire caulk broken or stretched clamps in multigang boxes. 6. Running boards needed within 6 feet of attic access. 7. Replace NM cable with damaged sheath in m. Bedroom. 8. Recept wall spacing exceeds 6 feet to left of sliding glass doors. Stationary glass counts as wall space. | ||
Electrical - Final | Failed | Disapproved | 100 | August 23, 2023 10:54 AM | Preston Byrd | 1. Could not locate ground rods. 2. Bond service raceway, and seal raceway in back of service panel. 3. Smokes not labeled in panel. 4. Hole in cabinet for diswhwasher cord needs to be large enough for plug to fit through. 5. Dishwasher missing junction box cover and cord cannot be over 6 1/2 feet. 6. Cannot use pop in boxes for everhead lghts over island, Must be rated for 50 pounds. 7. Wall spacing exceeds 6 feet in m. bedroom at bathroom door. | ||
Electrical - Spot Check | Available | |||||||
Electrical - Service Pole | Available | |||||||
Electrical - Temporary Service | Available | |||||||
Electrical - Above Ceiling | Available | |||||||
Electrical - Stocking | Available | |||||||
Electrical - Underground | Available | |||||||
Electrical - Panels/Service | Available | |||||||
Electrical - Roof Top | Available | |||||||
Electrical - Floor Heat | Available | |||||||
Electrical - Rough In | Passed | Approved | March 9, 2023 12:00 AM | Brian Craig | Corrections made | |||
Electrical - Final | Failed | Disapproved | 100 | August 25, 2023 10:17 AM | Richard Windon | Items 5 and 7 not corrected from previous report. 1. Could not locate ground rods. 2. Bond service raceway, and seal raceway in back of service panel. 3. Smokes not labeled in panel. 4. Hole in cabinet for dishwasher cord needs to be large enough for plug to fit through. 5. Dishwasher missing junction box cover and cord cannot be over 6 1/2 feet. 6. Cannot use pop in boxes for overhead lights over island, Must be rated for 50 pounds. 7. Wall spacing exceeds 6 feet in m. bedroom at bathroom door. | ||
Electrical - Final | Passed | Approved for Occupancy | August 28, 2023 8:53 AM | Richard Windon |