Related Permit Details
Application/Permit Information
Application/Permit Number:
Application Type:
Application Date:
Status:
Project Name:
Project Description:
Type | Status | Outcome | Cost | Date | Inspector | Checklist | Inspector Notes | General Notes |
---|---|---|---|---|---|---|---|---|
Electrical - Rough In | Failed | Disapproved | November 3, 2022 9:02 AM | Preston Byrd | 1. Nail plate missing at kitchen hood, to left of water heater. 2. Nm cable out of wall bottom of stairs above 3 gang sw box. 3. NM cable needs protection where blocking has been added on stair wall above 3 gang sw and bath switch. | |||
Electrical - Rough In | Passed | Approved | November 7, 2022 9:41 AM | Preston Byrd | corrections | |||
Electrical - Spot Check | Available | |||||||
Electrical - Service Pole | Available | |||||||
Electrical - Temporary Service | Available | |||||||
Electrical - Above Ceiling | Available | |||||||
Electrical - Stocking | Available | |||||||
Electrical - Underground | Available | |||||||
Electrical - Panels/Service | Available | |||||||
Electrical - Roof Top | Available | |||||||
Electrical - Floor Heat | Available | |||||||
Electrical - Final | Failed | Disapproved | May 24, 2023 9:13 AM | Preston Byrd | 1. Ground rods needs to be minimum of 6 feet apart. 2. Seal reaceway in back of panel. 3. Exterior panel cover does not fit correctly. 4. Exterior recept not labeled in panel or gfi protected. 5. Hood fan needs 15 amp MOCP. 6. Need recept within 24" of range to left and within 24" of end of countertop on penisular. 7. Light over island not mounted properly. 8. Missing recept plate in kitchen. 9. Label dishwasher disconnect. 10. Reidentify white wire in water heater disconnect. 11. Heat not marked with MOCP 12. Recept within 6 feet of kitchen sink at bathroom door needs GFI protection. | |||
Electrical - Final | Failed | Disapproved | June 1, 2023 8:52 AM | Preston Byrd | Heat not marked with MOCP | |||
Electrical - Final | Failed | Disapproved | June 6, 2023 12:00 AM | Brian Curran | Door code does not work | |||
Electrical - Final | Passed | Approved for Occupancy | June 9, 2023 12:00 AM | Brian Craig | Correction made. |