Related Permit Details
Application/Permit Information
Application/Permit Number:
Application Type:
Application Date:
Status:
Project Name:
Project Description:
Type | Status | Outcome | Cost | Date | Inspector | Checklist | Inspector Notes | General Notes |
---|---|---|---|---|---|---|---|---|
Electrical - Rough In | Failed | Disapproved | July 25, 2022 12:00 AM | Brandon Baird | Building placard needs to be onsite and buildings need to be mark which one address. No inspection done. | |||
Electrical - Rough In | Failed | Disapproved | August 10, 2022 12:00 AM | Brandon Baird | 1. NM cable hanging at kitchen and is staple more than 4' 6" in ceiling. 2. Still need nail plate at stairs. Stud was marked when preston did inspection | |||
Electrical - Spot Check | Available | |||||||
Electrical - Service Pole | Available | |||||||
Electrical - Temporary Service | Available | |||||||
Electrical - Above Ceiling | Available | |||||||
Electrical - Stocking | Available | |||||||
Electrical - Underground | Available | |||||||
Electrical - Panels/Service | Available | |||||||
Electrical - Roof Top | Available | |||||||
Electrical - Floor Heat | Available | |||||||
Electrical - Rough In | Failed | Disapproved | 100 | July 28, 2022 8:43 AM | Preston Byrd | 1. Move all recept out to face on firred out walls. 2. NM cable hanging out of ceiling of front porch. 3. Multigang boxes with broken or stretched clamps need to be replaced or fire caulk openings. 4. Nail plates missing on outside of framing where drilled holes are less than 1 1/4" to face of studs. 5. Recept at first floor bathroom is in the dining room and needs to be on dining circuit. 6. Bath exhaust fan 1st fl not grounded and 2nd fl hall bath fan ground screw is loose. 7. Strap all NM cables within 12" of all ceiling lights. 8. Dining room light box not grounded. 9. Staple NM cable 1 1/4" from face of studs at back outside recept and in hall at 2nd fl back bedroom. 10. Nail plates missing at home runs at top plate and need spacing of cables per 334.80. 11. Wall space requirements at back door for recepts. 12. Staple NM cable within 12" of 3 gang box at top of stairs. 13. Running boards. 14. Need recept on balcony. | ||
Electrical - Rough In | Failed | Disapproved | 100 | November 3, 2022 9:01 AM | Preston Byrd | Corrections not made from previous inspection. 1. Nail plate missing on outside of framing at top of stairs. Marked at first rough inspection. 2. NM cable hanging from ceiling in back room 1st floor and strap NM cable within 12" of all can lights. | ||
Electrical - Rough In | Canceled | Not Applicable | November 3, 2022 12:00 AM | Preston Byrd | ||||
Electrical - Rough In | Failed | Disapproved | August 16, 2022 8:06 AM | Preston Byrd | Corrections not made from previous inspection. 1. Nail plate missing on outside of framing at top of stairs. Marked at first rough inspection. 2. NM cable hanging from ceiling in back room 1st floor and strap NM cable within 12" of all can lights. Duct installer removed some of your staples. | |||
Electrical - Rough In | Failed | Disapproved | November 7, 2022 9:40 AM | Preston Byrd | NO access, Doors are screwed shut. Corrections not made from previous inspection. 1. Nail plate missing on outside of framing at top of stairs. Marked at first rough inspection. 2. NM cable hanging from ceiling in back room 1st floor and strap NM cable within 12" of all can lights. | |||
Electrical - Rough In | Available | |||||||
Electrical - Final | Failed | Disapproved | 100 | May 24, 2023 9:08 AM | Preston Byrd | 1. Recept to right of front door is greater than 6 feet from door. 2. Need recept within 24" of end of countertop at penisular. 3. Label dishwasher disconnect. 4. Hood fan needs 15 amp MOCP. 5. Reidentify white wire in water heater and disconnect. 6. Washer and dryer plates not installed. 7. Exterior recepts not labeled iin panel and not GFI protected. 8. Smokes not labeled in panel. 9. Ground rods need to be below grade. 10 A/C needs breaker lock or disconnect within sight of unit. 11. Recept in dining room within 6 feet of kitchen sink needs GFI protection. | ||
Electrical - Rough In | Failed | Disapproved | 200 | November 14, 2022 3:06 PM | Preston Byrd | Corrections not made from previous inspection. 1. Nail plate missing on outside of framing at top of stairs. Marked at first rough inspection. There is 2 locations that need nail plates on the outside of studs. | ||
Electrical - Rough In | Passed | Approved | November 18, 2022 9:21 AM | Preston Byrd | corrections made | |||
Electrical - Final | Failed | Disapproved | 100 | June 1, 2023 8:47 AM | Preston Byrd | All corrections not made. 1. Reidentify white wire in water heater disconnect. Reinstall tile backsplash in kitchen before reinspect. All plates needs to be installed in kitchen. | ||
Electrical - Final | Passed | Approved for Occupancy | June 6, 2023 12:00 AM | Brian Curran |