| Type | Status | Outcome | Cost | Date | Inspector | Checklist | Inspector Notes | General Notes |
|---|---|---|---|---|---|---|---|---|
| Plumbing - Water Heater | Available | |||||||
| Plumbing - Water Service | Failed | Disapproved | April 25, 2022 12:00 AM | John McLean | Not connected to city tap and in located in the same ditch of the sewer line | |||
| Plumbing - Below Slab | Failed | Disapproved | 100 | April 12, 2022 10:10 AM | John McLean | DWV system must be tested with water Seal seelves on both sides of foundation Sewer and water lines not connected to city tap | ||
| Plumbing - Rough In | Failed | Disapproved | July 29, 2022 3:19 PM | John McLean | Add hangers on 2 inch P-trap and closet flanges | |||
| Plumbing - Spot Check | Available | |||||||
| Plumbing - Final | Failed | Disapproved | May 17, 2023 10:43 AM | John McLean | Second floor seal around shower head on tub | |||
| Plumbing - Irrigation | Available | |||||||
| Plumbing - Above Ceiling | Available | |||||||
| Plumbing - Sewer | Passed | Approved | May 11, 2022 9:40 AM | John McLean | Partial only: Not connected to the city sewer or meter Note: plumber must reschedule for city connections | |||
| Plumbing - Storm Drainage | Available | |||||||
| Plumbing - Stocking | Available | |||||||
| Plumbing - Below Slab | Failed | Disapproved | April 22, 2022 9:10 AM | John McLean | Slab wet with water and muddy direct Note: need to label each DWV test risers to determine which slab is in relationship to your permit | |||
| Plumbing - Below Slab | Passed | Approved | April 25, 2022 9:50 AM | John McLean | ||||
| Plumbing - Water Service | Passed | Approved | May 11, 2022 9:45 AM | John McLean | Partial only: Not connected to the city sewer or meter Note: plumber must reschedule for city connections | |||
| Plumbing - Rough In | Failed | Disapproved | August 4, 2022 5:20 PM | John McLean | Add hangers on 2 inch P-trap Note: Ok to drop DWV and Hydro test | |||
| Plumbing - Rough In | Passed | Approved | August 5, 2022 9:40 AM | John McLean | ||||
| Plumbing - Water Service | Passed | Approved | February 24, 2023 12:51 PM | John McLean | ||||
| Plumbing - Sewer | Passed | Approved | February 24, 2023 12:51 PM | John McLean | ||||
| Plumbing - Final | Passed | Approved for Occupancy | May 24, 2023 4:38 PM | John McLean |