Related Permit Details
Application/Permit Information
Application/Permit Number:
Application Type:
Application Date:
Status:
Project Name:
Project Description:
Type | Status | Outcome | Cost | Date | Inspector | Checklist | Inspector Notes | General Notes |
---|---|---|---|---|---|---|---|---|
Electrical - Rough In | Failed | Disapproved | October 28, 2021 12:12 PM | Richard Windon | 1. need nail plate above two gang sw box at front door....nail plates in closet by front door...need nail plates above recpt in first fl bathroom....2. first fl ceiling separate nm cables for derating....3. need additional running boards....need nail plates throughout second fl and bedrooms | |||
Electrical - Final | Failed | Disapproved | March 3, 2022 3:11 PM | Preston Byrd | 1. A/C and water heater not installed. 2. Seal around main panel. 3. Need outlet within 24" of edge of kitchen sink to left. 4. Label disconnect for dishwaher and disposal, disposal not installed. 5. Check labeling of panel, Breakfast nook to be on 20 amp ckt. labeled as 15 amp in panel. 6. Need attic access, pull down stairs do not reach the floor. 7. Install bath fans. | |||
Electrical - Spot Check | Available | |||||||
Electrical - Service Pole | Failed | Disapproved | July 19, 2021 8:07 AM | Preston Byrd | Need seperate permit for service pole. GEC from ground rod must terminate on neutral bar. | |||
Electrical - Temporary Service | Available | |||||||
Electrical - Above Ceiling | Available | |||||||
Electrical - Stocking | Available | |||||||
Electrical - Underground | Available | |||||||
Electrical - Panels/Service | Failed | Disapproved | March 15, 2022 12:00 AM | Brian Dillard | need temp power permit for power befor final/CO | |||
Electrical - Roof Top | Available | |||||||
Electrical - Floor Heat | Available | |||||||
Electrical - Rough In | Passed | Approved | November 9, 2021 2:58 PM | Preston Byrd | ||||
Electrical - Final | Failed | Disapproved | March 15, 2022 12:00 AM | Brian Dillard | 1-need fire rings at back splash added in kitchen 2-label dish washer disconnect 3-panel schedule is not right, nook circuit needs to be 20 amp wire and breaker 4-label smoke circuit in panel | |||
Electrical - Final | Passed | Approved for Occupancy | March 17, 2022 8:28 AM | Preston Byrd | corrections. |