BUILDING - Footing |
Passed |
Not Applicable |
|
February 15, 2023 6:21 AM |
Steve Crist |
|
Approved for 3rd party approval per dept guidlines. |
|
BUILDING - Foundation |
Passed |
Not Applicable |
|
February 15, 2023 6:21 AM |
Steve Crist |
|
Approved for 3rd party approval per dept guidlines. |
|
BUILDING - Slab |
Available |
|
|
|
|
|
|
|
BUILDING - Framing |
Failed |
Disapproved |
100 |
February 16, 2023 12:58 PM |
Steve Crist |
|
Plans and permit in box in garage at 2103 are for another lot. Please provide correct plans and permit // fee added |
|
BUILDING - Insulation |
Passed |
Approved |
|
February 22, 2023 10:29 AM |
Karey McConnell |
|
Insulation Approved. Observed combination wall R-19 and 15. Batt R-38 Ceilings and Inaccessible areas. |
|
BUILDING - Final |
Passed |
Approved for Occupancy |
|
June 26, 2023 11:45 AM |
Michael Glass |
|
Impact Fee $1,375.00 due before CO |
|
BUILDING - Spot Check |
Available |
|
|
|
|
|
|
|
BUILDING - Other |
Available |
|
|
|
|
|
|
|
BUILDING - Angle |
Available |
|
|
|
|
|
|
|
BUILDING - Final/Multi-Family |
Available |
|
|
|
|
|
|
|
BUILDING - Above Ceiling |
Available |
|
|
|
|
|
|
|
BUILDING - Stocking |
Available |
|
|
|
|
|
|
|
BUILDING - Framing |
Failed |
Disapproved |
|
February 17, 2023 8:34 AM |
Steve Crist |
|
1) Install mending plate at top plate plumbing vent 1st floor powder 2) Screw ledger bands 1st and 2nd floor elevator room 3) Seal rods at 1st landing fire blocking and top of wall 3rd floor 4) Mending plate required top plate 3rd floor front bath at plumbing vent pipe // ok to insulate, leave reinspection items open. |
|
BUILDING - Framing |
Passed |
Approved |
|
February 22, 2023 10:29 AM |
Karey McConnell |
|
|
|