Type | Status | Outcome | Cost | Date | Inspector | Checklist | Inspector Notes | General Notes |
---|---|---|---|---|---|---|---|---|
Electrical - Rough In | Failed | Disapproved | November 3, 2022 8:56 AM | Preston Byrd | 1. NM cable out of wall at bottom of stairs above 3 gang sw box. 2. Replace 2 gang box in bath under stairs with KO missing. 3. Nail plate missing where NM cable is within 1 1/4" of face of framing with no protection. 4. Ground metal light box in back right bedroom 2 nd floor. 5. Kitchen, dining, back bedroom wall 1st floor. Nm cable has been removed. | |||
Electrical - Rough In | Passed | Approved | November 7, 2022 9:42 AM | Preston Byrd | corrections | |||
Electrical - Spot Check | Available | |||||||
Electrical - Service Pole | Available | |||||||
Electrical - Temporary Service | Available | |||||||
Electrical - Above Ceiling | Available | |||||||
Electrical - Stocking | Available | |||||||
Electrical - Underground | Available | |||||||
Electrical - Panels/Service | Available | |||||||
Electrical - Roof Top | Available | |||||||
Electrical - Floor Heat | Available | |||||||
Electrical - Final | Failed | Disapproved | May 24, 2023 11:56 AM | Preston Byrd | 1.Reidentify white wire in water heater and disconnect. 2. Need recept on countertop within 24" of end for wall spacing at penisular. 3. Recept within 6 feet of kitchen sink at bathroom door needs GFI protection. 4. 1st ground rod needs to be below grade. 5. Hood fan needs 15 amp MOCP. 6. Label dishwaher disconnect. 7. Seal raceway in back of service panel. 8. Exterior recept not marked in panel or GFI protected. 9. Need access to furnace in attic. | |||
Electrical - Final | Failed | Disapproved | 100 | June 1, 2023 8:49 AM | Preston Byrd | All corrections not made from previous inspection. 1. Need access to furnace in attic. 2. Patch wall at 4 gang switch in kitchen. | ||
Electrical - Final | Failed | Disapproved | 200 | June 6, 2023 12:00 AM | Brian Curran | Corrections not done, need 8' ladder to access attic | ||
Electrical - Final | Passed | Approved for Occupancy | June 9, 2023 12:00 AM | Brian Craig | Corrections made. |