Building Inspections |
Disapproved |
August 22, 2024 3:46 PM |
Permit # 24103473 reviewed by Doug Wegner on August 22 is Disapproved. Note the following concerns.
1. Life Safety plan sheet L.S.1.0 defines an exit path going through stock room 133. Review this condition with the NCBC section 1016 item 5.
2. Similar to item # 1 above , re-evaluate exit path at stock room 117.
3. Provide contractor with design details for guards , shown on page A9.11.
4. Evaluate the need for cane rail in at the stair area shown on sheet A7.8 C
5. Re-evaluate keyed locking mechanism on coil door showm at mall entrance on sheet A13.0b. See NCBC section 402.8.8
Send all communication/revisons to Plansreview@DurhamNC.gov . In the e-mail subject line provide the permit number.Do not send through D plans portal. |
|
Building Inspections - Electrical |
Disapproved |
August 15, 2024 8:18 AM |
electrical room 131 door needs to open out and be provided with panic hardware----will need gfi in room 131----larry.vaughan@durhamnc.gov |
|
Building Inspections - Plumbing |
Disapproved |
August 20, 2024 9:26 AM |
Remove all gas plans as from plumbing plans as stated in the check list. Send corrected plumbing only plans to plumbingplanreview@durhamnc.gov. CB |
|
Building Inspections - Mechanical |
Disapproved |
August 16, 2024 8:08 AM |
All gas plans are to be reviewed by the mechanical department- removed gas from plumbing drawings and resubmit in the portal and copy directly to me at Willie.hunter@durhamnc.gov- wjh |
|
Building Inspections - City Fire |
Approved |
August 15, 2024 4:36 PM |
Sprinkler and fire alarm permit required. MBM 8/15/24 |
|
Department Of Water Management - Cross Connection Control |
Approved |
August 20, 2024 11:08 AM |
8/29/24: If domestic shut off valve is not holding, Dick's/Transform is responsible for replacement prior to CO. MNH
Existing domestic to remain. New fire backflow being designed and permitted currently. CO contingent upon passing Fire backflow inspection by CCC. CCN: 4N24-W2NX (C) MNH |
|
Final |
Approved |
October 7, 2024 5:15 PM |
|
|
Building Inspections - Electrical |
Approved |
September 27, 2024 3:06 PM |
LV |
|
Building Inspections - Mechanical |
Approved |
August 19, 2024 7:20 AM |
wjh |
|
Building Inspections - Plumbing |
Disapproved |
August 21, 2024 1:18 PM |
Remove all gas plans as from plumbing plans as stated in the check list. Send corrected plumbing only plans to plumbingplanreview@durhamnc.gov. CB |
|
Building Inspections - Plumbing |
Approved |
September 4, 2024 6:43 AM |
CB |
|
Building Inspections |
Comments |
September 16, 2024 9:13 AM |
Permit # 24103473 reviewed by Doug Wegner on September 16th is Disapproved. Note the following
Provide further clarification on the egress dynamics at the mall entrance. Upon closer review it appears that the placement of the egress signs at the storage room doors are actually in the storage room and the egress door swings into the storage rooms which have less than 50 occupants ( 117, 114 ) . Less than 50 occupants door swing is acceptable. Clarify exit distance ,and exit discharge for occupants in storage room 114.
Send all communication to Plansreview@DurhamNC.gov In the e-mail subject line provide the permit number. |
|
Building Inspections |
Approved |
October 7, 2024 3:40 PM |
Permit # 24103473 reviewes by Doug Wegner on October 7 is Approved. |