Application/Permit Details

Application/Permit Information
Application/Permit Number:
Application Type:
Application Date:
Status:
Project Name:
Status Date:
Project Description:
Fee:
Permit Available Digitally
610 Duke Street
Name Role
Scherich Linda S Registered Owner
Brookwood Construction, Llc Contractor
Gestalt Architecture And Design Architect
PID PIN
105268 0822-20-80-0365
Approved Department Status Status Date Comments
Building Inspections Disapproved September 24, 2021 2:31 PM Permit # 21104742 reviewed by Doug Wegner on September 24 2021 is Disapproved. Note this review was completed remotely and the reviewer maybe reached at 919-323-6658 . Note the following : Provide additional information to address /clarify the grade level of the exit discharge at both exits. Attempts to view the property VIA Durham County GIS were not successful . Pictures/ relative grade elevations should clarify the concern. Send all communication to Doug.Wegner@DurhamNC.gov ; In the e-mail subject line provide the permit number.
Final Approved October 14, 2021 12:00 AM MPC
Building Inspections - Electrical Approved September 22, 2021 10:50 AM LV
Building Inspections - Plumbing Disapproved September 22, 2021 10:57 AM Many fixtures are not vented per 2018 NC Plumbing code. Cannot have horizontal dry vents as well. Please show 60 inch clear floor space for each ADA toilet. Need to show transfer shower elevation and dimensions. Send corrections to plumbingplanreview@durhamnc.gov. cb
Building Inspections - Mechanical Approved September 22, 2021 1:22 PM Review NC mechanical code 307.2.5 for Drain Line maintenance / wjh
Building Inspections - City Fire Approved September 22, 2021 10:36 AM MPC
Department Of Water Management - Cross Connection Control Disapproved September 22, 2021 12:49 PM Effective 11/1/2017, CCC will implement a $150.00 fee to perform plan review and re-review(s) associated with received building permit applications to the City/County Inspections Department. Use this link to receive details on how to apply for a CCC plan review application. <https://durhamnc.gov/DocumentCenter/View/31096/LDO-Instructions---Plan-Review?bidId>=
Planning Department Approved September 30, 2021 12:00 AM RWG 9/30/2021
Building Inspections - Plumbing Disapproved October 4, 2021 12:52 PM Fixtures are still not vented correctly. Cannot have horizontal dry vents in NC plumbing code. Washer must be a 3 inch drain per NC plumbing code. Send corrections to plumbingplanreview@durhamnc.gov. cb
Department Of Water Management - Cross Connection Control Approved September 24, 2021 2:31 PM New RPZ for suite isolation in Coach's Lounge 107 with drain to floor drain. MNH
Building Inspections Disapproved September 29, 2021 1:45 PM Permit # 21104742 reviewed by Doug Wegner on September 29th is Disapproved. Note this review was completed remotely and the reviewer maybe reached at 919-323-6658. Note the following : Clarify the design intent in terms of sprinkler system. It appears that this is project is a change of use from an S-2 to A-3 . Per table 1012.2.1 and paragraph 1012.2.1.1 of the 2018 NCEBC the proposed area would have to be sprinklered. Send all communication /revisions to Doug.Wegner@DurhamNC.gov
Building Inspections Approved September 30, 2021 11:26 AM Permit # 21104742 reviewed by Doug Wegner on September 30th 2021 is Approved. Note this review was completed remotely and the reviewer maybe reached at 919-323-6658.
Building Inspections - Plumbing Approved October 14, 2021 10:34 AM cb
Type Required Status Received Received Date
3 Drawings (Copies) Yes Complete Yes September 29, 2021 12:37 PM
Department Status Required Inspection Date Inspector Comments Sign Off Date
Building Approved for Occupancy Yes February 11, 2022 Todd Miller February 11, 2022
Electrical Approved for Occupancy Yes February 9, 2022 Brian Curran February 9, 2022
Plumbing Approved for Occupancy Yes February 11, 2022 Shane Broadhurst February 11, 2022
Mechanical Approved for Occupancy Yes February 11, 2022 Robert King February 11, 2022
City Fire Prevention Approved for Occupancy Yes February 11, 2022 Julius Richmond February 11, 2022
Cross Connection Approved for Occupancy Yes February 14, 2022 Tony Pickett February 14, 2022